Firestone, Colorado Sign Code & Sign Permit Guide

Wall, monument, and freestanding sign limits for Firestone by zoning district — cited to the exact code section, with the sign permit process. Every number is checked against the published code text before it ships.

Single-family residential & agricultural (RR, R-A, R-B, OTR, AG)

Zones like RR

§16.6.12.I.1: 'Table 6.12-2 below details the standards for the RR, R-A, R-B, OTR, PUD with Single Family, and AG Districts.' Legacy live code R-1 maps here per §16.2.2.C/F (R-1 -> R-A outside Old Town, R-1 -> OTR inside Old Town; both share this same rule so the split is immaterial for signs). PUD deliberately excluded — see zoning.cspResearchNote-adjacent PUD gotcha in the reference file.

4 sf max, 1 per lot
Wall sign area
100 sf max (text/logo only)
Freestanding sign area
8 ft (incl. monument)
Freestanding sign height
Not allowed
Wall sign illumination

Single enclosing shape (method unconfirmed): Section 16.6.12.G.1.a.i defines sign area as 'the area that completely encloses the limits of text and graphics of a sign, together with any frame or other material or color forming an integral part of the sign face.' No rectangle, multi-shape, or '8-line' method is specified — treat as the least favorable single-enclosure reading unless confirmed otherwise with the Town.

Wall Sign

Table 6.12-2
Maximum number1 per lot.
Maximum area4 sq ft.
Maximum heightNo standard stated (n/a in table).
IlluminationNot allowed.

Freestanding Sign

Table 6.12-2
Maximum number1 per entry point into the residential subdivision.
Maximum area100 sq ft (inclusive of text and logo only).
Maximum height8 ft (inclusive of sign and monument).
IlluminationAllowed.

Temporary Wall Sign

Table 6.12-5
Maximum number1 per building elevation.
Maximum area6 sq ft.
LightingNot allowed.
Maximum duration60 days per posting; 90 days/year total.

Temporary Freestanding Sign

Table 6.12-6
Maximum number1 per street frontage.
Maximum area8 sq ft.
Maximum height8 ft.
LightingNot allowed.
Setback2 ft from property lines.
Maximum duration60 days per posting; 90 days/year total.
See the exact numbers

Height, setback, area, count, and lighting limits for Single-family residential & agricultural (RR, R-A, R-B, OTR, AG) — cited to the code section, ready to quote from.

Get notified at launch
Before you submit
  • PUD-zoned parcels are NOT covered by this rule even though 'PUD with Single Family' appears in the table's own title — the live ZONECLASS='PUD' can't be distinguished from multi-family PUD, so PUD is left as its own gap.

Multi-family residential (R-C)

Zones like R-C

§16.6.12.I.2: 'Table 6.12-3 below details the standards for the R-C and PUD with multi-family zoning districts.' Legacy live code R-3 maps here per §16.2.2.E. PUD deliberately excluded — see PUD gotcha.

32 sf max, 1 per elevation
Wall sign area
100 sf max (text/logo only)
Freestanding sign area
8 ft (incl. monument)
Freestanding sign height
Allowed
Wall sign illumination

Single enclosing shape (method unconfirmed): Same §16.6.12.G.1.a.i single-enclosure wording as the single-family family — no rectangle/multi-shape/8-line method specified; treat as least favorable unless confirmed.

Wall Sign

Table 6.12-3
Maximum number1 sign per qualifying elevation.
Maximum area32 sq ft.
Maximum heightNo standard stated (n/a in table).
IlluminationAllowed.

Freestanding Sign

Table 6.12-3
Maximum number1 per entry point into the multi-family subdivision or site.
Maximum area100 sq ft (inclusive of text and logo only).
Maximum height8 ft (inclusive of sign and monument).
IlluminationAllowed.

Temporary Wall Sign

Table 6.12-5
Maximum number1 per complex.
Maximum area8 sq ft.
LightingNot allowed.
Maximum duration60 days per posting; 90 days/year total.

Temporary Freestanding Sign

Table 6.12-6
Maximum number1 per street frontage.
Maximum area32 sq ft.
Maximum height8 ft.
LightingNot allowed.
Setback2 ft from property lines.
Maximum duration60 days per posting; 90 days/year total.
See the exact numbers

Height, setback, area, count, and lighting limits for Multi-family residential (R-C) — cited to the code section, ready to quote from.

Get notified at launch
Before you submit
  • PUD-zoned parcels are NOT covered by this rule even though 'PUD with multi-family' appears in the table's own title — the live ZONECLASS='PUD' can't be distinguished from single-family PUD, so PUD is left as its own gap.

Non-residential (NC, RC, LI, OTC, PLI, OS)

Zones like NC

§16.6.12.I.3: 'Table 6.12-4 below details the standards for the NC, RC, LI, OTC, PLI and OS Zoning Districts.' Legacy live codes map per §16.2.3: C-1->NC, C-2/M-2->RC, EC/C-M/M-1->LI.

10% of elevation wall area (min 32 sf); Principal 100 sf, Secondary 32 sf each
Wall sign area
32 sf, 1 per frontage (+1 per 500 ft)
Freestanding sign area
200 sf / 35 ft (300 sf / 50 ft within 1,200 ft of I-25)
Development ID freestanding
10 ft
Freestanding sign height

Single enclosing shape (method unconfirmed): Same §16.6.12.G.1.a.i / G.2.a.i single-enclosure wording as the residential families — no rectangle/multi-shape/8-line method specified; treat as least favorable unless confirmed.

Wall Sign

Table 6.12-4, §16.6.12.G.1.a.ii
Aggregate area per elevation10% of total wall area for that elevation; tenants under 32 sq ft of wall area still get up to 32 sq ft.
Principal sign1 per elevation/tenant, max 100 sq ft.
Secondary signsUp to 4 per elevation/tenant, max 32 sq ft each.
Maximum heightNo standard stated (n/a in table).
IlluminationAllowed.

Freestanding Sign

Table 6.12-4
Maximum number1 per street frontage (+1 for every additional 500 ft of frontage).
Maximum area32 sq ft.
Maximum height10 ft.
IlluminationAllowed.

Freestanding — Development Identification

Table 6.12-4
Applies toDevelopments over 20 acres in size only.
Maximum number1 per arterial/collector frontage (+1 for every additional 1,000 ft of frontage).
Maximum area200 sq ft (300 sq ft within 1,200 ft of the I-25 right-of-way).
Maximum height35 ft (50 ft within 1,200 ft of the I-25 right-of-way).
IlluminationAllowed.

Electronic Message Display / Changeable Copy Display

§16.6.12.G.3
Where allowedIntegrated into a permanent sign's face, non-residential zones only.
Pixel pitch≤ 20 mm.
Maximum coverageOne-third (33.3%) of a permitted monument sign's face.
Message change rateNo more than once per 60 seconds; static images only, no transitions.
Brightness controlAutomatic dimmer software or solar sensors required.

Temporary Wall Sign

Table 6.12-5
Maximum number1 per street frontage or tenant space.
Maximum area40 sq ft.
LightingExternal only.
Maximum duration60 days per posting; 180 days/year total.

Temporary Freestanding Sign

Table 6.12-6
Maximum number1 per street frontage (+1 per additional 500 ft of frontage); doubled within 1,200 ft of I-25 ROW.
Maximum area32 sq ft (64 sq ft within 1,200 ft of I-25 ROW).
Maximum height8 ft (12 ft within 1,200 ft of I-25 ROW).
LightingExternal only.
Setback10 ft from all property lines.
Maximum duration60 days per posting; 180 days/year total.
See the exact numbers

Height, setback, area, count, and lighting limits for Non-residential (NC, RC, LI, OTC, PLI, OS) — cited to the code section, ready to quote from.

Get notified at launch
Before you submit
  • A known live data-quality gap was found for at least one large parcel in this zone family's real-world footprint (the King Soopers grocery/shopping-center parcel on Firestone Blvd) — its ZONECLASS still reads 'R-1' with the Town's own Notes field admitting the zoning couldn't be confirmed. An obviously-commercial address that resolves to a residential code should be flagged for manual confirmation, not trusted.
  • EMD/CCD signage is only permitted in this non-residential family (§16.6.12.G.3) — not in either residential family.

Sign permits in Firestone

Town of Firestone — Development Code, firestoneco.gov/175/Development-Code

Firestone sign code FAQ

What is the sign code for Firestone, Colorado?

Firestone's sign regulations are set by §16.6.12 Signs · Firestone Development Code, and vary by zoning district. Sightline tracks 3 verified zone families for Firestone below, each with wall, freestanding, and other sign-type limits cited to the exact section.

Do I need a permit for a sign in Firestone?

In nearly every Colorado municipality, including Firestone, permanent signs — wall signs, channel letters, cabinets, monument signs — require a sign permit. Firestone's permit process is linked below. Always confirm with the authority having jurisdiction before finalizing a design.

Look up an exact address in Firestone

Get the live zoning district and the sign limits that apply to a specific parcel, with a frontage calculator and a permit-ready citation.

Get notified at launch